Home Readiness Score · Aging in place
What your home already does well
Section 1
This report presents the results of a SafeHome Partners AI-powered home modification assessment for 100 Main Street. The assessment combines dimensional data from a CubiCasa floor plan scan with answers to a 20-question supplemental questionnaire completed by the family.
The home is a 2,549 sq ft two-story residence with four bedrooms and three bathrooms. All bedrooms are located on the 2nd floor, accessible only by staircase. The resident is currently mobile and independent on stairs — this is critically important, as it means modifications can be planned thoughtfully rather than executed in an emergency.
The questionnaire confirmed several immediate concerns despite current good mobility: 3 entry steps with one-side handrail only and no ramp space, narrow doorways at 28–30 inches at both the bathroom and the 1st-floor bedroom, a tub/shower combo on smooth tile, and partial nighttime lighting. These items carry fall risk regardless of current mobility level.
Section 2
The following summarizes all 20 supplemental questionnaire responses. Items are color-coded: red = confirmed risk factor, amber = attention needed, green = asset.
| Question | Answer |
|---|---|
| How many steps lead up to the front porch? | 3 steps |
| Is there a handrail on the entry steps? | One side only |
| What is the porch surface material? | Brick / pavers |
| Is there space beside the porch for a ramp? | No — landscaping needed |
| Width of doorway into 1st-floor bathroom? | 28–30 inches |
| Width of doorway into 1st-floor bedroom? | 28–30 inches |
| Are there raised thresholds between rooms? | None |
| Does the 1st-floor bathroom have grab bars? | Yes — toilet and shower/tub |
| Does the 1st-floor bath have a tub, shower, or both? | Tub / shower combo |
| What is the 1st-floor bathroom flooring? | Smooth tile |
| How many steps in the main staircase? | 13–15 steps |
| Does the staircase have handrails on both sides? | One side only |
| Is the staircase straight or curved? | Straight |
| Primary flooring in living room / sun room? | Luxury vinyl plank |
| Do flooring transitions create any height difference? | All flush |
| Is the bedroom-to-bathroom path lit at night? | Partial — some areas dark |
| What mobility aids does the resident currently use? | None currently |
| Can the resident climb stairs independently? | Yes, comfortably |
| What is the primary goal for modifications? | Future planning |
| Approximate total budget? | Flexible |
Section 3
Floor plans generated by CubiCasa scan of 100 Main Street. All room labels and fixture positions are as detected by the CubiCasa AI. Measurements are dimensionally accurate to within manufacturer tolerances.
1st Floor
1,753 sq ft
2nd Floor
796 sq ft
Section 4
The porch (16'8" × 5'9") is accessed via 3 steps with only one handrail on one side. The questionnaire confirms no space for a ramp without landscaping work. This is the highest-priority finding: without accessible entry, every other modification is meaningless for future wheelchair or walker use. Three steps at ~7 inches each equals 21 inches total rise, requiring a minimum 21-foot ADA-compliant ramp at a 1:12 slope. A contractor must evaluate whether a switchback ramp, platform lift, or landscape grading is most practical. Positive: brick/paver surface does not need replacement.
Basis: ADA Fair Housing: accessible entry required. CAPS: primary fall risk point for all mobility levels.
ADA minimum clear doorway width is 32 inches; CAPS recommends 36 inches for walker and wheelchair access. At 28–30 inches, a standard wheelchair has less than 3 inches of clearance, making independent bathroom access effectively impossible. Door widening requires removing the existing frame, potentially relocating a jack stud, and re-hanging a wider door. Permits are required in most jurisdictions. Budget to do this simultaneously with the bedroom doorway below.
Basis: ADA: 32" minimum clear doorway width. CAPS evaluation standard.
The 1st-floor bedroom (13'5" × 13'7") is the natural candidate for conversion to a primary bedroom as stair use becomes more difficult. Its doorway is also confirmed at 28–30 inches. Both doorways (bathroom and bedroom) should be widened in the same contractor visit to minimize cost. The bedroom itself is large enough for full wheelchair clearance: at 182 sq ft it easily accommodates a 60-inch wheelchair turning radius.
Basis: ADA: 32" minimum clear doorway. CAPS: bedroom accessibility requires 36" preferred.
A tub/shower combo with smooth tile is the highest-risk bathroom configuration for adults 65+. Stepping over a tub wall (typically 16–18 inches) while balancing on smooth tile accounts for the majority of serious bathroom falls. Positive: grab bars are already installed at toilet and shower/tub. Immediate action: add non-slip adhesive strips to the tub floor and a tub transfer bench. Long-term: convert to a curbless walk-in shower.
Basis: CAPS: tub/shower combos are the leading bathroom fall location. CDC: 235,000 bathroom injuries annually in the US.
The staircase is confirmed straight — excellent for stairlift installation (straight-rail $3,000–$5,500 vs. curved $8,000–$15,000). Immediate action: add a second handrail on the open side at 34–38 inches with a graspable profile (1.25–1.5 inch diameter). This is a same-day fix. Stairlift planning should begin now while the resident is still comfortable on stairs. Installation takes 3–4 hours. Stair width must be confirmed by a contractor (minimum 28 inches needed).
Basis: CAPS: bilateral handrails required. Proactive stairlift planning avoids costly emergency installation.
Round doorknobs require grip strength and wrist rotation, both commonly reduced by arthritis. Lever handles require only downward pressure. This home has an estimated 12–16 interior doors. A contractor can replace all hardware in a single visit using ADA-compliant lever sets.
Basis: CAPS standard modification. Low cost, high independence impact.
The questionnaire confirms some areas are dark at night on the path from bedroom to bathroom. Install plug-in motion-sensor night lights at 6–12 inch floor height along the route on both floors. The 2nd-floor hall (7'10" × 5'3") needs only one motion-sensor light. Replace all light switches with rocker-style at 42–44 inch height where possible.
Basis: CAPS: adequate lighting reduces nighttime fall risk by 35%.
Even before stairlift planning, the second handrail should be installed as a standalone project — any carpenter or handyman can complete this in under 4 hours. The rail must be continuous and graspable (1.25–1.5 inch round or oval profile), mounted at 34–38 inches above the stair nosing, with returns at top and bottom.
Basis: CAPS and IRC: bilateral graspable handrails on all stair runs.
Kitchen (17'3" × 11'0"): (1) Replace small knobs with D-ring or C-pull cabinet hardware, (2) Install full-extension pull-out shelves in lower cabinets to eliminate bending and step-stool use, (3) Evaluate lowering one counter section to 32–34 inches for seated food prep. Pantry should also receive pull-out shelving.
Basis: CAPS: kitchen modifications reduce fall risk from step-stool use and extend independent meal preparation.
The walk-in closet (9'5" × 8'0") is well-sized. Standard rods at 66–72 inches are unreachable from a seated position. Lower one rod to 48 inches maximum reach height and add a pull-down rod extender for the upper rod. Confirm closet entry doorway is at least 32 inches clear.
Basis: ADA: maximum forward reach 48". Side reach 9"–54".
Laundry (10'9" × 8'1"): If front-loading appliances are present, 12–15 inch pedestals raise the door to a more accessible height. If top-loading, the primary modification is non-slip flooring. Laundry rooms accumulate moisture and have elevated slip risk. The laundry door should also be included in the doorway widening evaluation.
Basis: CAPS: bending to retrieve laundry is a documented fall trigger for adults 65+.
The 1st-floor bedroom (13'5" × 13'7") is 182 sq ft — large enough for full wheelchair clearance. Begin planning now: assess proximity to the 1st-floor bath, evaluate whether a connecting pass-through can be added, and get a contractor estimate for a full en-suite bathroom addition. Acting without time pressure allows proper permitting, design, and competitive bidding.
Basis: Single-floor living is the #1 aging-in-place strategy for two-story homes.
As an immediate bridge while planning the tub conversion, apply 3M Safety-Walk or equivalent textured adhesive strips to the tub floor. Takes 20 minutes, costs under $30, and meaningfully reduces slip risk during the transition period. Grab bars are already installed — this completes the short-term bathroom safety package.
Basis: Simple interim fall prevention while longer-term conversion is planned.
The breakfast nook (12'5" × 9'3") is a daily-use space. Standard chairs at 17–19 inch seat height make sit-to-stand difficult. Consider chairs with armrests at 18–20 inch seat height — armrests provide a push-up surface — or a counter-height table with stools for easier standing transfers.
Basis: CAPS: seating with armrests significantly eases sit-to-stand for adults with reduced lower-body strength.
A handheld showerhead on a sliding bar enables seated showering and lowers the spray head for use from a shower chair. Installs in under an hour on any standard shower arm. Recommended for all three bathrooms; prioritize the 1st-floor bathroom.
Basis: CAPS: handheld showerheads enable independent bathing with reduced fall risk.
The sun room (15'8" × 13'8") connects to the living room. The questionnaire reports all transitions are flush — verify specifically at the sun room entry on a contractor visit, as sun rooms often have a slightly raised threshold from original construction. If over ½ inch, install a transition reducer strip ($20–$40).
Basis: Verification only — questionnaire reports flush transitions throughout.
Section 5
Based on these findings and a goal of future planning, the following phased approach is recommended. With no current mobility limitations there is no emergency — but acting now ensures better contractor access, lower costs, and no rushed decisions.
Your project timeline & readiness trajectory
In your client portal, the work is organized into scheduled stages — do-it-yourself or contractor — and your readiness score climbs as each stage completes.
On schedule, your home reaches full aging-in-place readiness by mid-2027 for a cumulative spend of about $32,000 — sequenced so the highest-impact safety items come first.
Section 6
The following items must be verified on-site before any work begins. This report is generated from scan and questionnaire data — all measurements require physical confirmation.
Home Readiness Score · Child Safety
What your home already does well
Section 1
This report presents the results of a SafeHome Partners AI-powered child safety assessment for 100 Main Street. The assessment combines dimensional data from a CubiCasa floor plan scan with answers from the family's supplemental questionnaire focused on the age and developmental stage of children in the home.
The home is a 2,549 sq ft two-story residence. Two children — ages 2 and 5 — are active throughout all areas including the 2nd floor, accessed via an open staircase. The assessment identified 4 critical hazards and 5 recommended modifications. Total estimated remediation cost is low ($1,100–$1,700), and the majority of critical items are DIY-accessible.
The questionnaire also confirmed two high-consequence hazards that are invisible to floor plan analysis: unanchored tall dressers in two 2nd-floor bedrooms, and cleaning products stored under the kitchen sink without a safety latch. Both are addressed in the critical findings below.
Section 2
The main staircase (13–15 steps, straight run) is completely ungated and accessible from both the 1st-floor living area and the 2nd-floor hallway. For a 2-year-old, this is the highest-consequence hazard in the home. Install pressure-mounted gates at both top and bottom immediately. Hardware-mounted gate required at the top landing.
Basis: CPSC: stair falls are the #1 cause of unintentional injury in children under 5. AAP: gate both top and bottom until age 6 minimum.
Questionnaire confirmed unanchored dressers in both 2nd-floor bedrooms. Furniture tip-over injuries account for approximately 25,000 ER visits per year in the U.S. Anti-tip straps are available for under $15 per unit and take 15 minutes to install. All furniture over 30 inches tall should be anchored.
Basis: CPSC Anchor It! campaign. ASTM F2057 stability standard for clothing storage furniture.
All 2nd-floor bedroom windows can open beyond the 4-inch maximum recommended for homes with young children. Window guards or window stops should be installed on all accessible 2nd-floor windows. Window stops that prevent opening beyond 4 inches are preferred over full guards (which require a release mechanism for fire egress).
Basis: NYC Local Law 57 (nationwide best practice): 4-inch maximum opening for children under 10. AAP policy statement on window falls.
The questionnaire confirmed that cleaning products, dishwasher pods, and other toxic substances are stored under the kitchen sink in an unlocked, low cabinet. Poisoning is the leading cause of accidental death in children under 5. Install a magnetic or spring-loaded cabinet lock immediately and relocate high-toxicity items to a high shelf or locked cabinet.
Basis: Poison Control: 50%+ of all pediatric poisoning calls involve cleaning products. CPSC.
Standard outlet covers are present but not confirmed as tamper-resistant. Tamper-resistant receptacles (TRR) require simultaneous pressure on both slots to open and cannot be defeated by a child inserting a single object. Replace all outlets within reach of children with TRR outlets or install sliding safety covers as an interim measure.
Basis: NEC 2008+: TRR required in new construction in all living areas. CPSC electrical injury data.
Questionnaire confirmed water heater is set to 140°F. At this temperature, scalding can occur in under 5 seconds on a child's skin. The AAP recommends setting the water heater to 120°F for all homes with young children. This is a free fix (adjust the thermostat dial) if the unit is accessible.
Basis: AAP: 120°F maximum for homes with children under 6. CPSC scald burn prevention guidelines.
The path from the 2nd-floor bedrooms to the bathroom is unlit at night. Motion-activated nightlights at floor level significantly reduce nighttime falls for both children and adults. Install at bedroom exits and along the hallway to the bathroom.
Basis: CPSC home safety guidelines. Pediatric Emergency Care.
The stove knobs are at standard standing height but accessible to a 5-year-old standing on a step stool. Stove knob covers prevent children from turning on burners unsupervised. Alternatively, always use rear burners and turn pot handles inward. Knob covers are a low-cost supplement to behavioral safeguards.
Basis: Safe Kids Worldwide: kitchen burns are among the most common childhood injuries ages 1–4.
The 1st-floor bathroom has smooth tile floor confirmed by questionnaire. Non-slip bath mats and tub treads are recommended inside the tub and immediately outside it. A non-slip bath seat should also be considered for the 2-year-old during bath time to prevent falls while standing.
Basis: CPSC: bathroom falls are the leading cause of injury in children ages 1–4 in the home.
Section 3
Home Readiness Score · Accessibility & Disability
What your home already does well
Section 1
This report presents the results of a SafeHome Partners AI-powered accessibility and disability assessment for 100 Main Street. The resident is a manual wheelchair user seeking maximum independence in a single-story living arrangement. The assessment combines CubiCasa floor plan data with questionnaire responses focused on mobility type, assistive device needs, and daily living goals.
The home presents moderate-to-significant accessibility barriers. All bedrooms are on the 2nd floor — inaccessible by wheelchair without a lift. The 1st floor has a small bedroom (currently used as an office) and a bathroom with a doorway measuring 28–30 inches — below the 32-inch ADA minimum. The exterior entry requires 3 steps with no alternative. These three barriers are the primary focus of the critical findings.
Positive findings: the main living area is open and wide enough for wheelchair navigation today. The luxury vinyl plank flooring throughout the 1st floor is roll-friendly and does not need replacement. The straight staircase is compatible with a future motorized stairlift if 2nd-floor access becomes a goal.
Section 2
The porch is accessed via 3 steps (approximately 21 inches total rise) with no ramp, lift, or graded alternative. This is a category-1 barrier — without accessible entry, independent wheelchair ingress/egress is impossible. Options include: (a) a modular aluminum ramp (1:12 slope = 21 feet minimum run — feasible if the yard allows), (b) a vertical platform lift ($4,000–$7,000 installed), or (c) grading and a concrete apron to the side yard. A contractor site visit is required to determine which option is feasible given lot constraints.
Basis: ADA 2010 §402–405: accessible route from arrival point to entrance required. Fair Housing Act: accessible entry for wheelchair users.
The 1st-floor bathroom doorway measures 28–30 inches per questionnaire. A standard manual wheelchair requires 32 inches clear width minimum; 36 inches is strongly preferred. Widening to 36 inches requires a structural evaluation (load-bearing wall determination), but the 1st-floor hall corridor appears to have room for a 3-4 inch expansion on the non-load-bearing side. An offset (Z-hinge) door hinge can recover 2 inches at no structural cost and should be evaluated first.
Basis: ADA 2010 §404.2.3: 32-inch minimum clear width. ANSI A117.1: 36 inches preferred for full turning approach.
The existing tub/shower combo is incompatible with wheelchair transfer without significant modification. A roll-in shower conversion (minimum 36"×36", preferably 36"×60" for attendant access) is required for independent bathing. This is the highest-cost single item in the report. A curbless threshold is mandatory. A fold-down shower bench, handheld showerhead, and grab bars at transfer height should be included in the same renovation.
Basis: ADA 2010 §608: roll-in shower specifications. ADA shower seat and grab bar placement standards.
The 1st-floor room currently used as an office measures 28–30 inches at the doorway — the same barrier as the bathroom. If this room is to be converted to the primary bedroom (necessary for single-floor living), it must be widened to a minimum 32 inches clear. The floor plan shows adjacent wall space that should accommodate widening without structural work.
Basis: ADA 2010 §404.2.3. Fair Housing Design Manual: accessible route to all primary spaces.
The 1st-floor corridor connecting the living area to the bathroom and bedroom measures approximately 36 inches wide per floor plan data. A standard wheelchair requires a 60-inch turning diameter for a full 180° turn. While the hallway itself may accommodate straight-line travel, the T-intersection at the bathroom entry does not allow an in-place turn. This may be resolved without construction by repositioning furniture and removing a non-load-bearing half-wall (verify with contractor).
Basis: ADA 2010 §304.3: 60-inch turning space required at each accessible space entry point.
The questionnaire did not confirm grab bars at the toilet location. ADA-compliant grab bars on the side wall and rear wall at the toilet are required for safe wheelchair-to-toilet transfer. This item can be installed before the full bathroom renovation and should be completed immediately if the resident is using the 1st-floor bathroom in any capacity today.
Basis: ADA 2010 §604.5: side and rear grab bar placement at water closets.
Standard kitchen counter height is 36 inches, which is above comfortable reach for a wheelchair user (ADA recommends 28–34 inches for seated reach). Lowered countertop sections at sink and primary prep area, knee clearance below, and a pull-out work surface are the priority items. A full kitchen renovation is not required — targeted section lowering with knee clearance is the most cost-effective approach.
Basis: ADA 2010 §804: kitchen accessibility requirements. Universal Design reach range standards.
The home has round door knobs throughout. ADA standards require lever handles or loop pulls operable with a closed fist — round knobs require tight grasping and twisting, which is not possible for many wheelchair users or individuals with reduced hand strength. Lever handle replacements are available for $15–$40 per door and are a DIY installation.
Basis: ADA 2010 §309.4: operable parts — no tight grasping, pinching, or twisting required.
Section 3
It starts with a CubiCasa floor plan scan — takes about 5 minutes with your smartphone.